Single-storey terraced housing in Malaysia does not provide thermal comfort to its occupants due to poor dissipation of heat from solar irradiation unless mechanical cooling
is installed, which adds to the urban heating island problem. This study is a simple assessment of natural ventilation performance of terrace houses which by law are built with
an airwell and sized according to regulations. A typical room of 3 m x 4 m x 3 m with an adjacent airwell has been investigated by CFD simulation assuming ambient temperature
of 30°C and atmospheric pressure of 101.3 kPa. The results show that with an airwell-chimney of 2.55 m above the roof the test room air velocity could reach 0.6 ms-1
for thermal comfort; while without the protruded chimney adverse cold inflow set in, and the indoor air flow velocity ranged from as low as 0.08 ms-1 to 0.21 ms-1.
However, when the protruded chimney was not installed, but with a wiremesh-based blocker of adverse cold inflow installed on the airwell outlet, the indoor air flow velocity
consistently reached 0.2-0.3 ms-1, which was about 45% higher than that without the blocker, and was within the recommended range for thermal comfort.
The wiremesh blocker of adverse cold inflow could be an option to ventilate effectively single-storey terrace houses without the need of installing tall chimneys.
ASHRAE 55. 2009. Indoor Air Quality Guide - Best Practices for Design, Construction, and Commissioning - Strategy 7.6.7 Air Movement. (https://app.knovel.com/hotlink/pdf/id:kt008N3T92/indoor-air-quality-guide/strategy-7-6-7-air-movement). Last accessed on 24 November 2020.
Chen, Y.S. & Kim, S.W. 1987. Computation of turbulent flows using an extended k-e turbulence closure model. NASA contractor report no. NASA CR-179204.
Chu, C. M. C. & Rahman, M. M. 2009. A Method to Achieve Robust Aerodynamics and Enhancement of Updraft in Natural Draft Dry Cooling Towers. ASME Summer Heat Transfer Conference. 19-23 July 2009. San Francisco, Calif., U.S.A. Paper no. HT2009-88289.
Chu, C. M. C., Rahman, M.M., Kumaresan, S. & Phang, H.K. 2014. Heat Balance of a Simulated Natural Convection Vertical Cylinder with Inlet Constriction and Flow Reversal at Chimney Exit. Proceedings of the International Conference on Heat Transfer and Fluid Flow. 11-12 August, 2014. Prague, Czech Republic. Paper no 173.
Haaland, S.E. 1983. Simple and Explicit Formulas for the Friction Factor in Turbulent Pipe Flow. Journal of Fluids Engineering, 105(1), 89-90.
Khanal, R. & Lei, C.W. 2012. Flow reversal effects on buoyancy induced air flow in a solar chimney. Solar Energy, 86, 2783-2794.
Leng, P.C., Ahmad, M.H., Ossen, D.R., Ling, G.H.T., Abdullah, S., Aminudin, E., Liew, W.L. & Chan, W.H. 2019. The Impact of Air Well Geometry in a Malaysian Single Storey Terraced House. Sustainability, 11, 5730, doi:10.3390/su11205730, MDPI.
Linden, P.F., Lane-Serff, G.F. & Smeed, D.A. 1990. Emptying filling boxes: the fluid mechanics of natural ventilation. Journal of Fluid Mechanics, 212, 309-335.
Moosavi, L., Mahyuddin, N., Ab Ghafar, N. & Ismail, M.A. 2014. Thermal performance of atria: An overview of natural ventilation effective designs. Renewable and Sustainable Energy Reviews, 34, 654-670.
Sinnott, R.K. & Towler, G. 2009. Coulson and Richardson’s Chemical Engineering Volume 6 - Chemical Engineering Design (5th Edition). Oxford: Pergamon Press.
Tinker, J.A., Ibrahim, S.H. & Ghisi, E. 2004. An Evaluation of Thermal Comfort in Typical Modern Low-Income Housing in Malaysia. Buildings IX, 1-10. ASHRAE.
Urrego, J., Ko, A.I., da Silva Santos Carbone, A., Paião, D.S.G., Sgarbi, R.V.E., Yeckel, C.W., Andrews, J.R. & Croda, J. 2015. The Impact of Ventilation and Early Diagnosis on Tuberculosis Transmission in Brazilian Prisons. The American Journal of Tropical Medicine and Hygiene, 93(4), 739–746.